Basic Info
Container Type | 20′′ or 40′′ Standard Shipping Container |
Transport Package | Container |
Specification | Containerized Canopy |
Trademark | ALONG BIOGAS |
Origin | China |
HS Code | 8502200000 |
Production Capacity | 1000 Set/Year |
Product Description
Items | Data |
Biogas genset | |
Brand | Yuchai |
Genset Model | AYG1000 |
Structure Form | Separate type |
Rated Power ( kW/kVA ) | 1000/1250 |
Continuous power ( kW ) | 800 |
Rated Current ( A ) | 1640 |
Rated Voltage ( kV ) | 440/240 |
Rated Frequency ( Hz ) | 60 |
Rated Power Factor | 0.8(LAG) |
Noise ( dB ( A ) ) | < 102 |
Exhaust Emission Targets | Meet the standard GB/T 22343-2008 oil industry uses biogas internal combustion generator. |
Rated Condition Max. Gas Consumption ( m3/h based on 21.6M/Nm3 ) | 427 |
Fuel Consumption Rated ( Nm3/kW.h ) | 0.36 |
Genset Dimensions ( L×W×H ) ( mm ) | 5380×1650×2426 |
Gneset Net Weight ( kg ) | 14000 |
Output Power Dynamic Performance Index | |
No-load Voltage Setting Range | 95% - 105% |
Steady-state Voltage Regulation | ≤ ±1% |
Transient Voltage Regulation | ≤ -15% - +20% |
Voltage Recovery Time | ≤ 3s |
Voltage Fluctuation Rate | ≤ ±0.5% |
Transient Frequency Adjustment Rate | ≤ ±10% |
Frequency Stabilization Time | ≤ 5s |
Line Voltage Waveform Sinusoidal Distortion Rate | ≤ 2.5% |
Biogas Engine | |
Brand | Austria AVL tech Yuchai engine |
Structure Type | V type, water cooled, 4 stroke, turbocharge, inter-cooling |
Model | NY792D120TL |
Cylinder No. Bore * Stroke - Displacement | V12-200×210-79.2 |
Rated Power ( kW ) | 1100 |
Rated Speed ( r/min ) | 1500 |
Speed Type | American woodward integrated electronic throttle automatic speed adjustment |
Combustion & Ignition Mode | American woodward electric control rarefied combustion |
Gas Intake Method | Water cooled exhaust gas turbocharged, inter-cooling |
Starting Method | 24VDC |
Overhaul Period ( h ) | ≥30000 |
Brush-less Alternator | |
Brand / Model | Xingnuo/XN6G |
Structure Form | Single bearing, brush-less / with automatic |
Rated Capacity ( kW/kVA ) | 1000/1250 |
Rated Voltage ( kV ) | 400/230 |
Rated Current ( A ) | 1800 |
Rated Frequency ( Hz ) | 50 |
Power Factor | 0.8(LAG) |
Connecting Wire Method | 3 phase 4 wires |
Insulation Class | H |
Protection Class | IP23 |
Gneset Management & Control System | |
Operation Mode | Automatic / Manual |
Engine Control System | American Woodward |
Genset Control System | Comap |
Genset Operation Date Display | Large screen liquid crystal display |
Digital Government System | American Woodward |
Automatic Fuel Regulation & Control System | |
Natural Gas Quality | Meet the II class biogas requirements of GB 17820-2012 bioGas |
Natural Gas Flow Control | Automatic adjustment of fuel control valve |
Gas Mixer | Venturi Mixer |
Gas pressure Regulator | Italy Fiorentini Minireg diaphragm type gas pressure regulator |
Fuel Control Method | Close loop control, lean burn |
Gas Maximum Inlet Pressure | <50kPa |
Gas Minimum Inlet Pressure | ≥5kPa |
Maximum Fuel Gas Temperature | ≤40ºC |