ItemsData
Biogas genset
BrandYuchai
Genset ModelAYG1000
Structure FormSeparate type
Rated Power ( kW/kVA )1000/1250
Continuous power ( kW )800
Rated Current ( A )1640
Rated Voltage ( kV )440/240
Rated Frequency ( Hz )60
Rated Power Factor0.8(LAG)
Noise ( dB ( A ) )< 102
Exhaust Emission TargetsMeet the standard GB/T 22343-2008 oil industry uses biogas internal combustion generator.
Rated Condition Max. Gas Consumption ( m3/h based on 21.6M/Nm3 )427
Fuel Consumption Rated ( Nm3/kW.h )0.36
Genset Dimensions ( L×W×H ) ( mm )5380×1650×2426
Gneset Net Weight ( kg )14000
Output Power Dynamic Performance Index
No-load Voltage Setting Range95% - 105%
Steady-state Voltage Regulation±1%
Transient Voltage Regulation-15% - +20%
Voltage Recovery Time≤ 3s
Voltage Fluctuation Rate±0.5%
Transient Frequency Adjustment Rate±10%
Frequency Stabilization Time≤ 5s
Line Voltage Waveform Sinusoidal Distortion Rate2.5%
Biogas Engine
BrandAustria AVL tech Yuchai engine
Structure TypeV type, water cooled, 4 stroke, turbocharge, inter-cooling
ModelNY792D120TL
Cylinder No. Bore * Stroke - DisplacementV12-200×210-79.2
Rated Power ( kW )1100
Rated Speed ( r/min )1500
Speed TypeAmerican woodward integrated electronic throttle automatic speed adjustment
Combustion & Ignition ModeAmerican woodward electric control rarefied combustion
Gas Intake MethodWater cooled exhaust gas turbocharged, inter-cooling
Starting Method24VDC
Overhaul Period ( h )≥30000
Brush-less Alternator
Brand / Model Xingnuo/XN6G
Structure FormSingle bearing, brush-less / with automatic
Rated Capacity ( kW/kVA )1000/1250
Rated Voltage ( kV )400/230
Rated Current ( A )1800
Rated Frequency ( Hz )50
Power Factor0.8(LAG)
Connecting Wire Method3 phase 4 wires
Insulation ClassH
Protection ClassIP23
Gneset Management & Control System
Operation ModeAutomatic / Manual
Engine Control SystemAmerican Woodward
Genset Control SystemComap
Genset Operation Date DisplayLarge screen liquid crystal display
Digital Government SystemAmerican Woodward
Automatic Fuel Regulation & Control System
Natural Gas QualityMeet the II class biogas requirements of
GB 17820-2012 bioGas
Natural Gas Flow Control Automatic adjustment of fuel control valve
Gas MixerVenturi Mixer
Gas pressure RegulatorItaly Fiorentini Minireg diaphragm type gas pressure regulator
Fuel Control MethodClose loop control, lean burn
Gas Maximum Inlet Pressure <50kPa
Gas Minimum Inlet Pressure ≥5kPa
Maximum Fuel Gas Temperature ≤40ºC